Описание Tester of acid batteries with a voltage of 12 and 24 V megeon 81024
Megaon 81024 is a handy portable 12/24 volt acid battery tester. Lightweight, compact, device powered by a tested battery. To correctly display the results, he needs to enter only the cold start current, 5 standards are supported in which this parameter is indicated (DIN, EN, IEC, CCA, JIS), the table from the delivery set is used to translate the latter. Residual life is calculated based on the data obtained when measuring the internal resistance according to the IEEE 1118-1996 method, and voltage. In addition, it allows you to fix the peak values at the terminals in starting modes, the consumption of various loads and check the charging circuit. It will find wide application in pre-sales testing and diagnostics of vehicle power supply systems.
Peculiarities:
Powered by tested battery
Display backlight
Calculating remaining spare capacity
Startup battery check, Workload check
Checking the charging system
Type of tested battery : Lead-acid
Tested battery voltage: 12/24 V
Power : From tested battery
Checked battery parameters: Voltage, internal resistance
On-board network parameters to be checked : Start test, load test, charging system test
Supported cold start standards : CCA, EN, IEC, DIN
Automatic reserve capacity calculation (range): 12 . 200 Ah
Manual calculation of the reserve capacity (in the range): 1 . 1000 Ah
Setting current range in CCA : 100 . 1700 A
Setting current range in IEC : 100 . 1000 A
Setting current range in EN : 100 . 1700 A
Setting current range in DIN : 100 . 1000 A
Checking JIS-marked batteries: Conversion to CCA according to the attached table
Delivery set: Megeon tester 81024 - 1 pc. Protective holder - 1 pc. Translation table - 1 pc. Operation manual - 1 copy. Warranty card - 1 copy.
Remaining reserve capacity (RC): Calculation in % of initial value
Residual cold cranking current (CCA): Indirect measurement in Amps of the selected standard
Battery internal resistance: Measured in mΩ (milliohms) according to IEEE1118-1996 method
Battery Voltage: Measured in Volts
Field of recommendations: Recommendations for replacement are of a general advisory nature, in each individual case it is necessary to make an informed decision, taking into account all influencing factors.
Fixing the minimum voltage on the battery during start-up: Measured in Volts
Fixing the minimum voltage on the battery during the test: Measured in Volts
Fixing the minimum voltage on the battery during the test: Measured in Volts
Fixing the maximum voltage on the battery during the test: Measured in Volts
Power supply: From the tested battery (9...35 V)
Dimensions (with protection): 210 x 100 x 40 mm
Weight (with protection): 520 g
Operating conditions 1: Temperature 0...50 °С
Relative humidity 20...70%
Transportation and storage conditions: Temperature -20...60 °С
Relative humidity 20...80%
no condensation
Hide